Solution to Water Leakage in the Water Tank of a Constant Temperature and Humidity Test Box

Views: 6     Author: Site Editor     Publish Time: 2023-07-14      Origin: Site

Inquire

facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button
Solution to Water Leakage in the Water Tank of a Constant Temperature and Humidity Test Box

The constant temperature and humidity test chamber can simulate various temperature and humidity environments. It can simulate the product under the combined conditions of temperature and humidity in the general climate environment (high and low temperature operation and storage, Temperature cycling, high temperature and high humidity, condensation test). It can detect whether the adaptability and characteristics of the product itself have changed, and whether the product will crack under the environment (low temperature and low humidity, high temperature and low humidity, high temperature and high humidity drop to low temperature and low humidity, etc.) Damage (in addition, the amount of static electricity in the air in low humidity environments is more than 30 times that of general environments, and according to statistics, 59% of semiconductor damage rate is caused by static electricity).

1. Check if the water level box on the right side of the constant temperature and humidity test box is too high, which ultimately leads to excessive water entering. If this is the case, the user only needs to adjust the water level box. In addition, it is recommended to communicate and communicate with the manufacturer of the constant temperature and humidity test box when adjusting the water level line box, and have the original manufacturer assign professional technical personnel to repair on the spot to prevent abnormal faults from occurring.

2. Check whether the place where the constant temperature and humidity test chamber is placed is leveled. The Dry-bulb temperature tube will be skewed due to the same slanting angle of view, and then water will drip down. At this time, the fault can be easily solved by moving the machine or equipment to a flat road.

3. It is necessary to check the water circuit of the constant temperature and humidity test box again to see if the water valve is opened too large, resulting in sufficient water flow. If this is the case, adjusting the water valve down can solve this problem.